Description
Model
|
CW-3000
|
Voltage
|
AC 110V/ 220-240V
|
Frequency
|
50/60Hz
|
Current
|
0.4~1A
|
Machine Power
|
0.1kW
|
Max.lift
|
10M
|
Max.flow
|
10L/min.
|
Protection
|
Flow Alarm
|
Tank Capacity
|
9L
|
Inlet & Outlet
|
OD 10mm Barbed Connector
|
N.W.
|
9.5kg
|
G.W.
|
12kg
|
Dimension
|
470mm*270*370mm (L*W*H)
|
Package Dimension
|
590*380*470mm (L*W*H)
|
CW-3000 Series is professional cooling machine referring to international, advanced thermolysis cooling system design, suitable for small water-cooled cooling devices requested machinery. The Industrial Water Chiller has a patent Certificate, CE and RoHS Certificate. It has been sold largely to Europe, South America, Asia and other markets. Economic cooling equipment, easy to install and operate, compact and easily movable.
It is designed for cooling the one CO2 glass laser tube under 60W/80W of the laser engraving and cutting machine.
Install steps:
1. Open the package to check if the machine is intact and all the necessary accessories are completed.
2. Open the mouth screw on the top of machine, add cooling water (Please don’t power the machine without water).
3. According to system conditions, connect the water isnlet and outlet pipe well.
4. Connect the power cable, turn the power switch (Note: Don’t let the water overflow).
5. Check the radiator water level again (Keep the distance between water level and mouth is 80–150mm).
Notice:
Cooling machine no use for long time or in transport must keep emptying the cooling water.
It is designed for cooling the UV lamp under 300W of the UV printer machine.
It is strictly forbidden to plug and run the cooler without feeding water.
Cooler should be placed in a well-ventilated, dry environment place and away from heat sources. Please keep at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 10cm between obstructions and air inlets of two sides.
To protect laser tubes , the radiator fan of cooler will suspend to work when water temperature is lower (about 10℃) , and it will restart to run when water temperature rises to higher (about 20℃).
To ensure good heat dissipating, please open the lid to clean the dirt after the cooler used in long-term.
Working in cold north area, it is better to use noncorrosive.
Remarks: CW3000 water chillers are equipped high speed fans inside, NOT able to control the water temperature.